1. 程式人生 > >Linux下 IPMItool配置方法(MSI主機板)

Linux下 IPMItool配置方法(MSI主機板)

一、IPMI-IP配置(本機登陸方式

1,ipmitool -I open shell      //進入本地BMC shell

[[email protected] ~]# ipmitool -I open shell
ipmitool> 

2,lan set 1 ipsrc static      //設定ipsrc的型別為靜態

ipmitool> lan set 1 ipsrc static

3,lan set 1 ipaddr 192.168.200.100   //設定靜態IP為192.168.200.100

ipmitool> lan set 1 ipaddr 192.168.200.100
Setting LAN IP Address to 192.168.200.100

4,lan set 1 netmask 255.255.255.0 //設定子網掩碼為255.255.255.0

ipmitool> lan set 1 netmask 255.255.255.0
Setting LAN Subnet Mask to 255.255.255.0

5,lan set 1 defgw ipaddr 192.168.200.1   //配置閘道器為192.168.200.1 

ipmitool> lan set 1 defgw ipaddr 192.168.200.1
Setting LAN Default Gateway IP to 192.168.200.1

6,lan print  //列印IPMI配置資訊,檢查是否正確

ipmitool> lan print
Set in Progress         : Set Complete
Auth Type Support       : NONE MD2 MD5 PASSWORD OEM 
Auth Type Enable        : Callback : NONE MD2 MD5 PASSWORD OEM 
                        : User     : NONE MD2 MD5 PASSWORD OEM 
                        : Operator : NONE MD2 MD5 PASSWORD OEM 
                        : Admin    : NONE MD2 MD5 PASSWORD OEM 
                        : OEM      : 
IP Address Source       : Static Address
IP Address              : 192.168.200.100
Subnet Mask             : 255.255.255.0
MAC Address             : d8:cb:8a:f6:6e:e5
SNMP Community String   : AMI
IP Header               : TTL=0x40 Flags=0x40 Precedence=0x00 TOS=0x10
BMC ARP Control         : ARP Responses Enabled, Gratuitous ARP Disabled
Gratituous ARP Intrvl   : 0.0 seconds
Default Gateway IP      : 192.168.200.1
Default Gateway MAC     : 00:00:00:00:00:00

Backup Gateway IP       : 0.0.0.0
Backup Gateway MAC      : 00:00:00:00:00:00
802.1q VLAN ID          : Disabled
802.1q VLAN Priority    : 0
RMCP+ Cipher Suites     : 0,1,2,3,6,7,8,11,12,15,16,17
Cipher Suite Priv Max   : caaaXXaaaXXaaXX
                        :     X=Cipher Suite Unused
                        :     c=CALLBACK
                        :     u=USER
                        :     o=OPERATOR
                        :     a=ADMIN
                        :     O=OEM

7,exit  //退出shell

二、IPMI 測試

1,使用同網段電腦開啟IE 輸入192.168.200.100登陸

2,也可通過SSH登入

二、IPMI 遠端操作命令

 遠端SSH開機: 

ipmitool –H (IP地址) –I lanplus –U (使用者名稱) –P (密碼) power on 

遠端關機: 

ipmitool –H (IP地址) –I lanplus –U (使用者名稱) –P (密碼) power off 

遠端重啟: 

ipmitool –H (IP地址) –I lanplus –U (使用者名稱) –P (密碼) power reset 

檢視server狀態: 

 ipmitool -I lanplus -H (IP地址) –U (使用者名稱) –P (密碼)  chassis status

ipmitool> chassis status
System Power         : on
Power Overload       : false
Power Interlock      : inactive
Main Power Fault     : false
Power Control Fault  : false
Power Restore Policy : always-on
Last Power Event     : ac-failed 
Chassis Intrusion    : inactive
Front-Panel Lockout  : inactive
Drive Fault          : false
Cooling/Fan Fault    : false
Front Panel Control  : none

更改密碼: 

 ipmitool -I lanplus -H (IP地址) –U (使用者名稱) –P (密碼)  user list

 ipmitool -I lanplus -H (IP地址) –U (使用者名稱) –P (密碼) user set password 2 newpass 

檢視風扇,電壓,溫度感測器

 ipmitool -I lanplus -H (IP地址) –U (使用者名稱) –P (密碼) sdr elist full

ipmitool> sdr elist full
Temp_CPU0        | 01h | ns  |  3.0 | No Reading
Temp_CPU1        | 02h | ns  |  3.0 | No Reading
Temp_CPU0_DIMM1  | 03h | ns  |  3.0 | No Reading
Temp_CPU0_DIMM2  | 04h | ns  |  3.0 | No Reading
Temp_CPU0_DIMM3  | 05h | ns  |  3.0 | No Reading
Temp_CPU0_DIMM4  | 06h | ns  |  3.0 | No Reading
Temp_CPU1_DIMM1  | 07h | ns  |  3.0 | No Reading
Temp_CPU1_DIMM2  | 08h | ns  |  3.0 | No Reading
Temp_CPU1_DIMM3  | 09h | ns  |  3.0 | No Reading
Temp_CPU1_DIMM4  | 0Ah | ns  |  3.0 | No Reading
Temp_BMC         | 0Bh | ok  |  3.0 | 35 degrees C
Temp_ENV         | 0Ch | ok  |  3.0 | 33 degrees C
Voltage_5VSB     | 40h | ok  |  7.1 | 5.15 Volts
Voltage_3VSB     | 41h | ok  |  7.2 | 3.32 Volts
Voltage_P5V      | 42h | ok  |  7.3 | 5.10 Volts
Voltage_P3V3     | 43h | ok  |  7.4 | 3.36 Volts
Voltage_P12V     | 44h | ok  |  7.5 | 12 Volts
Voltage_VBAT     | 45h | ok  |  7.6 | 2.79 Volts
Voltage_VCC_CPU0 | 46h | ok  |  7.7 | 1.80 Volts
Voltage_VCC_CPU1 | 47h | ok  |  7.8 | 1.80 Volts
Voltage_PVDDQ_AB | 48h | ok  |  7.9 | 1.21 Volts
Voltage_PVDDQ_CD | 49h | ok  |  7.10 | 1.21 Volts
Voltage_PVDDQ_EF | 4Ah | ok  |  7.11 | 1.21 Volts
Voltage_PVDDQ_GH | 4Bh | ok  |  7.12 | 1.21 Volts
CPU_FAN0         | B0h | ok  |  7.1 | 1400 RPM
CPU_FAN1         | B1h | ok  |  7.1 | 1500 RPM
SYS_FAN1         | B2h | ns  |  7.1 | No Reading
SYS_FAN2         | B3h | ok  |  7.1 | 3100 RPM
SYS_FAN3         | B4h | ok  |  7.1 | 3000 RPM
SYS_FAN4         | B5h | ns  |  7.1 | No Reading
SYS_FAN5         | B6h | ok  |  7.1 | 3100 RPM
SYS_FAN6         | B7h | ns  |  7.1 | No Reading

檢視SEL事件中的感測器編號和名稱

 ipmitool -I lanplus -H (IP地址) –U (使用者名稱) –P (密碼) sdr list

ipmitool> sdr list
Temp_CPU0        | no reading        | ns
Temp_CPU1        | no reading        | ns
Temp_CPU0_DIMM1  | no reading        | ns
Temp_CPU0_DIMM2  | no reading        | ns
Temp_CPU0_DIMM3  | no reading        | ns
Temp_CPU0_DIMM4  | no reading        | ns
Temp_CPU1_DIMM1  | no reading        | ns
Temp_CPU1_DIMM2  | no reading        | ns
Temp_CPU1_DIMM3  | no reading        | ns
Temp_CPU1_DIMM4  | no reading        | ns
Temp_BMC         | 35 degrees C      | ok
Temp_ENV         | 33 degrees C      | ok
Voltage_5VSB     | 5.15 Volts        | ok
Voltage_3VSB     | 3.36 Volts        | ok
Voltage_P5V      | 5.10 Volts        | ok
Voltage_P3V3     | 3.36 Volts        | ok
Voltage_P12V     | 12 Volts          | ok
Voltage_VBAT     | 2.79 Volts        | ok
Voltage_VCC_CPU0 | 1.80 Volts        | ok
Voltage_VCC_CPU1 | 1.80 Volts        | ok
Voltage_PVDDQ_AB | 1.21 Volts        | ok
Voltage_PVDDQ_CD | 1.21 Volts        | ok
Voltage_PVDDQ_EF | 1.21 Volts        | ok
Voltage_PVDDQ_GH | 1.21 Volts        | ok
CPU_FAN0         | 1400 RPM          | ok
CPU_FAN1         | 1500 RPM          | ok
SYS_FAN1         | no reading        | ns
SYS_FAN2         | 3100 RPM          | ok
SYS_FAN3         | 3000 RPM          | ok
SYS_FAN4         | no reading        | ns
SYS_FAN5         | 3100 RPM          | ok
SYS_FAN6         | no reading        | ns
Watchdog2        | 0x00              | ok

檢視SELlog資訊

 ipmitool -I lanplus -H (IP地址) –U (使用者名稱) –P (密碼) sel list

ipmitool> sel list
   1 | 01/01/2012 | 00:03:49 | System Event | Timestamp Clock Sync | Asserted
   2 | 10/30/2018 | 10:23:08 | System Event | Timestamp Clock Sync | Asserted

清除SELlog資訊

 ipmitool -I lanplus -H (IP地址) –U (使用者名稱) –P (密碼) sel clean

檢視FRU資訊

 ipmitool -I lanplus -H (IP地址) –U (使用者名稱) –P (密碼) fru print

ipmitool> fru print
FRU Device Description : Builtin FRU Device (ID 0)
 Chassis Type          : Rack Mount Chassis
 Chassis Part Number   : S1451
 Board Mfg Date        : Wed Jan  1 14:40:00 2014
 Board Mfg             : MSI
 Board Product         : S1451
 Board Part Number     : MS-S1451
 Product Manufacturer  : EPS
 Product Name          : MSIS145
 Product Part Number   : MS-S145
 Product Version       : 1.0

FRU Device Description : AST2400-S1451   
 Chassis Type          : Rack Mount Chassis
 Chassis Part Number   : S1451
 Board Mfg Date        : Wed Jan  1 14:40:00 2014
 Board Mfg             : MSI
 Board Product         : S1451
 Board Part Number     : MS-S1451
 Product Manufacturer  : EPS
 Product Name          : MSIS145
 Product Part Number   : MS-S145
 Product Version       : 1.0